YKK/YXKX Series High Voltage Motor

YKK/YXKK series motors stand out for high efficiency, high energy savings, low vibration, low weight, compact structure, reliable operation and convenient maintenance. The motors comply with the national standard GB755 “rotating electrical machines-rating and performance” and the relevant international standards, and suitable to drive compressors, fans, water pumps, industrial freezers, conveyor belts, crushers and other general machinery. Please specify the requirements in the order when motors are mounted on high moment of inertia equipment like blower, coal pulverizer, rolling mill, winch and belt conveyor.
The motor frame is welded by steel plate, and offer excellent rigidity and vibration resistance performance. They are manufactured with F insulation structure and VPI vacuum pressure impregnation process. The non-stop filling and discharging bearing system ensures a convenient maintenance.
Special requirements on voltage, power, frequency and mounting dimension can be customized. YKS water cooling motors have the same power range, performance and dimension as Y series.


  • Frame size: 355-630MM (6KV)、 400-630MM (10KV)
  • Rated power: 220KW-1120KW (6KV) 、220KW-1120KW (10KV)
  • Product Detail

    Product Tags

    YKK/YXKK series motors comply with the national standard GB755 and the relevant international standards,.The motor frame is welded by steel plate, and offer excellent rigidity and vibration resistance performance. They are manufactured with F insulation structure and VPI vacuum pressure impregnation process. The non-stop filling and discharging bearing system ensures a convenient maintenance.

    YKK/YXKK Technical Data

    Frame size 355-630MM (6KV)、 400-630MM (10KV)
    Rated power 220KW-1120KW (6KV) 、220KW-1120KW (10KV)
    Rated voltage 6KV 10KV
    Installation Method IMB3
    Degrees of protections IP44、IP54、IP55
    Cooling Method IC611、IC616
    Number of poles 2\4\6\8\10\12
    Degrees of insulation F
    Environmental conditions Altitude should be lower than 1000 m above sea level; -15°C ~+40°C

    Mounting and overall dimensions(6KV)

    ykk

     Frame

    NO.

     Poles

     Mounting dimensions(mm)

    Overall dimensions(mm)

    A

    B

    C

    D

    E

    F

    G

    H

    K

    AC

    AD

    HD

    AB

    BB

    BA1

    BA2

    AA

    J

    J1

    H1  L

    355

    2

    630

    900

    315

    80

    170

    22

    71

    355

    28

    1120

    1020

    1500

    784

    1380

    490

    550

    170

    224

    93

     28   2450

    4,6

    100

    210

    28

    90

    784

    1380

    490

    550

    170

    224

    100

    28

    400

    2

    710

    1000

    375

    90

    170

    25

    81

    400

    35

    1260

    1050

    1700

    884

    1540

    570

    640

    200

    234

    200

     28   2600

    4,6,8,10

    335

    110

    210

    28

    100

    450

    2

    800

    1120

    400

    100

    90

    450

    35

    1420

    1120

    1900

    964

    1680

    490

    560

    200

    229

    282

     32   2900

    4

    355

    120

    32

    109

    964

    1680

    600

    670

    229

    6,8,10,12

    130

    250

       32

    119

    189

    500

    2

    900

    1250

    560

    110

    210

    28

    100

    500

    42

    1600

    1200

    2200

    1094

    1830

    660

    730

    200

    244

    364

     32 3300

    4

    475

    130

    250

    32

    119

    1094

    620

    690

    6,8,10,12

    140

    36

    128

    560

    2

    1000

    1400

    560

    130

    32

    119

    560

    1800

    1260

    2400

    1176

    1640

    680

    750

    200

    345

    370

    40   3550

    4

    500

    150

    36

    138

    680

    750

    380

    6,8,10,12

    160

    300

    40

    147

    630

    2

    1120

    1600

    560

    140

    250

    36

    128

    630

    48

    2000

    1360

    2720

    1360

    2050

    725

    815

    200

    510

    510

    46   3800

    4

    530

    170

    300

    40

    157

    1360

    2050

    710

    780

    200

    510

    480

    6,8,10,12

    180

    45

    165

    1360

    2050

    710

    780

    200

    510

    480

    Note: 1. The data listed in the table is for users' reference. In case of any discrepancy with the random file, the random file shall prevail.
    2. When cooling IC616 is used, the size HD and L shall be in accordance with the agreement.

    Mounting and overall dimensions(10KV)

    ykk

     Frame

    NO.

     Poles

     Mounting dimensions(mm)

    Overall dimensions(mm)

    A

    B

    C

    D

    E

    F

    G

    H

    K

    AC

    AD

    HD

    AB

    BB

    BA1

    BA2

    AA

    J

    J1

    H1

    L

    400

    2

    710

    1000

    375

    90

    170

    25

    81

    400

    35

    1260

    1050

    1700

    884

    1540

    570

    640

    200

    299

    151

    28

    2600

    4,6

     710  1000

    335

    110

    210

    28

    100

    2400

    450

    2

    800

    1120

    400

    90

    170

    25

    81

    450

    35

    1420

    1170

    1900

    964

    1680

    490

    560

    200

    294

    243

    32

    2900

    4

    355

    110

    210

    28

    100

    964

    1680

    600

    670

    200

    294

    243

    32

    2600

    6,8,10

    500

    2

    900

    1250

    560

    100

    210

    28

    90

    500

    42

    1420

    1100

    2200

    1094

    1830

    660

    730

    200

    309

    341

    32

    3300

    4

    475

    130

    32

    119

    1094

    620

    690

    3000

    6,8,10,12

    250

    650

    650

    560

    2

    1000

    1400

    560

    130

    32

    119

    560

    1800

    1250

    2400

    1176

    1940

    680

    750

    200

    461

    355

    40

    3550

    4

    500

    150

    36

    138

    3300

    6,8,10,12

    160

    300

    40

    147

     3800

    630

    2

    1120

    1600

    560

    140

    250

    36

    128

    630

    48

    2000

    1300

    2700

    1336

    2050

    725

    815

    200

    481

    455

    40

    3800

    4

    530

    170

    300

    40

    157

    1336

    2050

    710

    780

    200

    481

    480

    46

    3600

    6,8,10,12  180 300 45  165

    Note:
    1. The data listed in the table is for users' reference. In case of any discrepancy with the random file, the random file shall prevail.
    2. The total L size of the bipolar motor is the size when the cooling mode is IC616.

    微信图片_202306011430573
    微信图片_202306011430571

  • Previous:
  • Next:

  • Write your message here and send it to us